TimeWalker® II IntimaLaser™
Er:YAG and Nd:YAG laser platform for gynecological applications, with Fotona SMOOTH® and Fotona PIANO® operating modes. The technologies presented by the manufacturer include the G-Runner robotic scanner.
- Er:YAG · Nd:YAG
- Fotona SMOOTH® · Fotona PIANO® · G-Runner
- IntimaLaser™ II and IntimaLaser™ II Pro versions
A dual-wavelength gynecology platform.
TimeWalker® II IntimaLaser™ combines Er:YAG and Nd:YAG in one platform for gynecological applications. The technologies presented by the manufacturer include the G-Runner robotic scanner. The manufacturer also lists the GClear single-use speculum and a dedicated intraurethral handpiece.
It is available as IntimaLaser™ II and IntimaLaser™ II Pro; the Pro version adds Nd:YAG operating modes (FRAC3, PIANO, VERSA, PLLT, QCW) according to the manufacturer's table.
Technologies as named by the manufacturer
- Fotona SMOOTH®
- Fotona PIANO®
- G-Runner
- GClear speculum
- MicroPilot M100
- R09-2Gu intraurethral
- MarcCo®
Accessories & handpieces
- G-RunnerRobotic scanner for fully automated gynecological treatments, with GClear single-use speculum. For IncontiLase®, IntimaLase®, RenovaLase® and ProlapLase®.
- PS03XEr:YAG handpiece · spot 2–7 mm · patterned spot. For SMOOTH tightening.
- R11Er:YAG handpiece · spot 2–7 mm · full spot. For skin resurfacing, removal of benign lesions and tissue ablation.
- PEN 1.0 DEr:YAG handpiece · 1 mm spot · full spot. For micro-ablation and soft-tissue surgery.
- FS01Fractional Er:YAG handpiece · 250 μm · 9 × 9 mm, 81 spots. For episiotomy and caesarean scars, and stretch marks.
- R33-TNd:YAG handpiece · spot 2–10 mm · full spot. For lichen sclerosus, vulvodynia and vulvar pain from specific disorders, and aesthetic applications.
- R30YNd:YAG handpiece · 15 and 20 mm spots · full spot.
- R09-2GuEr:YAG handpiece · 4 mm spot · full spot, with tube for intraurethral applications. For IncontiLase® Intra.
- R27CSmall surgical Nd:YAG handpiece for 600 μm fibres. For surgical applications.
- R08Surgical Er:YAG handpiece · 0.45 mm spot · full spot. For micro-ablation and soft-tissue surgery (labiaplasty).
- MicroPilot M100Micromanipulator for guiding the laser beam with high precision. For condylomas, vulvar and cervical lesions (CIN I–II).
- MarcCo® S, M and LNd:YAG handpiece · 10 / 24 / 43 mm spot · collimated · full spot. For ComfortLase™ (healing and pain management).
Applications
Information for healthcare professionals. Applications are presented as described by the manufacturer. Approved indications for use, contraindications and availability may vary by country. The manufacturer's official instructions apply to appropriate use.
- IncontiLase® / IncontiLase® Intra
- IntimaLase®
- RenovaLase®
- ProlapLase®
- LichenLase™
- ComfortLase™
- Removal of genital & cervical lesions
- Scar tissue remodelling
- Labiaplasty (minor surgery)
Technical data
Values as published by the manufacturer. For the standard version the table lists no Nd:YAG values.
- Er:YAG — IntimaLaser™ II
- 12 W · 0.9 J · MSP, SMOOTH
- Er:YAG — II Pro
- 20 W · 1.5 J · MSP, SP, LP, VLP, SMOOTH
- Nd:YAG — II Pro
- 30 W · 20 J · FRAC3, PIANO, VERSA, PLLT, QCW
- R09-2Gu
- Spot 4 mm · intraurethral tube
- R33-T
- Nd:YAG · 2–10 mm
- R30Y
- Nd:YAG · 15 & 20 mm
See the TimeWalker® II IntimaLaser™ in action.
The Evomedica team is at your disposal for demonstrations and technical information.